- Controller: STC-1000 Thermostat.
- Logic: If Tempstorage>38°F→ Activate Pump & Fan.
- Hardware: Submersible 12V Pump → 1/4" Copper Coil → 120mm PWM Fan.
- Bulkhead Overflow: Installed at 6.5" height (0.5" below the storage grid).
- Air Seal: Exterior P-trap loop to prevent "Cold Air Dumping" from the drain.
- Low-Level Alarm: Magnetic float switch wired to a 5V buzzer to signal when ice depletion is imminent.
| Item Type |
Suitability |
Notes |
| Leafy Greens |
⭐⭐⭐⭐⭐ |
High humidity prevents wilting. |
| Beverages |
⭐⭐⭐⭐⭐ |
Rapid pull-down due to forced convection loop. |
| Meats |
⭐⭐⭐ |
Must be stored in watertight containers to avoid contamination. |
| Mushrooms |
⭐ |
Too humid; store in paper bags inside breathable plastic tubs. |
- 2026-03-24: Bulkhead seal successful. Zero leakage over a 6-hour test with 4" of water.
- 2026-03-25: Procured the STC-1000 unit. Calibration testing shows a ±0.5°C variance from reference thermometers.